* At least one of them must be transferred to obtain the LED condition.
The following power-up conditions on the system status LED are
abnormal:
LED not lit—Check the power supply and cabling. If power is available
and the LED stays off, call Verint Video Solutions customer service for
assistance.
Steady red LED persisting more than 10 seconds—There is an
internal error that prevents the device from starting normally. Power
down the device, wait 30 seconds, then power it up. If the condition
persists, call Verint Video Solutions customer service.
Flashing green (1 sec.
intervals)
The firmware has started, the device is connected to
the network, but no video/audio/serial* data is
transmitted.
Flashing green (0.2 sec.
intervals)
The firmware has started, the device is connected to
the network, and video/audio/serial* data is
transmitted.
Three consecutive red
blinks every 2 sec.
No video source is detected and no video is
transmitted.
Flashing green-red (1 sec.
intervals)
The device is undergoing a firmware update.
Flashing red (0.1 sec.
intervals)
The device is being identified.
Condition Indication